Products Home - Products
ELCB
DPNL EARTH LEAKAGE CIRCUIT BREAKER
Print this page
Bookmark this page
PDF View
Tell a friend
Live Messenger
Skype Me
E-mail Us
Consulting Product Information
Share |
Application
DPNL leakage protective breaker is used in the single phase residence circuit of AC 50Hz/60Hz,rated voltage 230V,used as electron shock protection.It can protect civil electron circuit form overload and short circuit This product has advantages of small volumn,high breaking capacity zero,and live wire are cut off at the same time,also protecting person from electric shock when the live wire connected opposite.This product conforms to IEC61009,GB16917 Stardands.
Main Technical Parameter
Rated
current (A)
No.of
pole
Rated
voltage (V)
Rated current of
frame
Rated leakage
operating
Rated leakage non-operating current
Rated
leakage breaking time
Breaking
capacity (A)
6,10,16,
20,25,32
1+N
230
32
30
15
≤0.1s
3000
Overload Trip Characteristic
Rated
current(A
Rated
voltage(A)
Limited
time
Pre-engage
result
Start state
Note
1.13In
all
t≥1h
non-trip
cold state
1.45In
all
t<1h
trip
heat state
he current rise steadily to a fixed value within 5s
2.55In
all
1<t<60s
non-trip
cold state
5In
all
t≥0.1s
trip
old state
Open the supplementary switch,connect the power
10In
all
t<0.1s
trip
old state
Open the supplementary switch,connect the power
Installation dimensions
Motion Characteristic Curve
About Us    Products    News    Order Online    Contact Us 浙公网安备 33038202004288号  Copyright © 2011 Zhejiang Kivi Electrical Co., LTD.
POWERED BY ESHION
流量统计